BV 6045DV

ADANI BV 6045DV Checkpoint X-ray Inspection System

Back to Baggage Inspection Section

The X-ray baggage system BV 6045DV provides the effective inspection of large parcel, small cargo and other items.

Dual view system is able to produce two separate simultaneous images from perpendicular orientations providing a complete image of an inspected object, reducing the need for repositioning and rescanning thus enabling rapid, accurate and comprehensive threat detection.

BV 6045DV allows identification of weapons, explosives (including plastic explosives), drugs, primers and dangerous objects, which are a safety hazard by identification of substances with an effective atomic number.

Dual energy imaging of the system with automatic color coding of materials having different atomic numbers helps screening specialits to easily identify dangerous objects inside any parcel

GENERAL SPECIFICATIONS:

DIMENSIONS

Tunnel dimensions
Width
Height

620±3 mm [24.4"]
450±5 mm [17.7"]
Overall dimensions, not more than*
Width
Height
Length

1200 mm [47.2"]
1350 mm [53.2"]
2350 mm [92.5"]
Weight, not more than* 800 kg [1764 lbs]

*Stated performance as measured by ADANI Test Kit


CONVEYOR BELT

Maximum distributed load on the conveyor belt, max 200 kg [441 lbs]
Conveyor height (without a trolley) 700 mm [27.6"]
Conveyor speed 0.22±0.03 m/s [43.3 ft./min]
Noise level 0 - 65 dB(A)

X-RAY UNIT

Anode voltage
- Low-dose operating mode
- Standard operating mode
- High penetration mode


-
140 kV
160 kV

Beam direction diagonally upward and diagonally sideward
Cooling system oil bath
Film safety up to ISO 1600 (33 DIN)

DETECTOR UNIT

Detector type two L-shaped multiunit array
Dual-energy detector Yes
Grey levels 65536
**Wire detectability (minimum diameter of copper wire/standard operating mode) 40 AWG
**Steel penetration, low-dose operating mode -
**Steel penetration, standard operation mode 30 mm guaranteed
**Steel penetration, high penetration mode 36 mm guaranteed

**Stated performance as measured by ADANI Test Kit

TECHNICAL SPECIFICATIONS OF THE OPERATOR'S AWS ***

Display and control At least 19.5” (1920x1080)
Operation system MS Windows 8.1 Industry, the fault-tolerant OS configuration

***Specifications can be changed on request

POWER SUPPLY

Line voltage 230 VAC ± 10% / 120 VAC ± 5%
Line frequency 50 / 60 Hz
Power consumption less than 1.2 kVA

ENVIRONMENTAL REQUIREMENTS

****Operation:
ambient temperature

0° to +40 °С

**** Operating temperature can be expanded up to +50°C (option)

CERTIFICATES AND STANDARDS

ISO 9001:2008 Certified
CE conformity
Compliant with standards for :
cabinet X-ray systems - US FDA
Center for Devices and Radiation
Health, 21-CFR 1020.40

RADIATION SAFETY

The design of the system provides radiation leakage attenuation limited to 1.0 μSv/hr (0.1 mR/hr) or lower at any accessible point at the distance of 0.1 m from the external surface of the system. The dose rate intensity at the workstations of the personnel does not exceed 1.0 μSv/hr.

OPTIONS:

  • Entry / exit / folding rollers;
  • Operator’s desk;
  • Stand for monitors and specialized keyboard;
  • Touchscreen operation functionality
  • Set of test objects;
  • Uninterruptible Power Supply.

BV 6045DV